© Coleman Powermate, Inc. 10-06
Stationary Standby Electric Generator - 11,200 WATTS - MODEL PM401211
Stationary Standby Electric Generator - 9,7 00 WATTS - MODEL PM400911
IMPORTANT SAFETY INSTRUCTIONS – Please make certain that persons who are to install, operate and maintain
this equipment thoroughly read and understand these instructions prior to operation. SAVE THESE INSTRUCTIONS
— This manual contains important instructions that should be followed during installation and maintenance of the
generator and battery.
Record the model and serial numbers of your generator below:
Model Number
____________________
Serial Number
____________________
Date Purchased
____________________
OWNERS MANUAL
MODELS: PM401211
AND PM400911
Read and understand all safety precautions in this manual and other
manuals included with this product before installing, operating and maintaining this
equipment. Failure to comply with instructions in this manual could result in personal
injury, property damage, and/or voiding of your warranty. Coleman Powermate WILL
NOT be liable for any damage because of failure to follow these instructions.
WARNING:
200-2341 - Revision C
Seitenansicht 0
1 2 3 4 5 6 ... 47 48

Inhaltsverzeichnis

Seite 1 - OWNERS MANUAL

© Coleman Powermate, Inc. 10-06Stationary Standby Electric Generator - 11,200 WATTS - MODEL PM401211Stationary Standby Electric Generator - 9,7 00

Seite 2

10 200-2341Once the generator is anchored in its final position, itis ready for electrical connections. The generator issupplied with two terminal bl

Seite 3 - WARNING:

200-2341 11A ground fault circuit interrupting (GFCI) receptacleis provided with the generator to power the batterycharger for reliable starting. It

Seite 4 - CAUTION:

12 200-23411122KKWW WWIIRRIINNGG DDIIAAGGRRAAMM ((CCPP220000 CCOONNTTRROOLLLLEERR))RELAY PIN WIRE NUMBER30 185 1386 987 13RELAY WIRING INFORMATION

Seite 5

200-2341 13The engine driving the generator is engineered toprovide reliable power on either Liquefied Propane Vapor(LPG) or Natural Gas. For proper o

Seite 6

14 200-2341After electrical connections are complete, the nextinstallation step is to connect a fuel supply to the unit.The fuel inlet fitting supplie

Seite 7

200-2341 15In cases where liquefied propane vapor is selectedas the fuel of choice, insure fuel delivery in the gaseousstate, with a minimum energy c

Seite 8

16 200-2341To insure reliable starting in most weatherconditions, it is important to properly match a battery tothe requirements of the generator. The

Seite 9 - 200-2341 9

200-2341 17To install the battery, begin by placing the battery (A)into the battery rack as shown in Fig G. Orientation ofthe battery terminals is ac

Seite 10 - DDAANNGGEERR

18 200-2341After completing all installation procedures, read andunderstand the operating instructions for the generatorcontroller. Know how the cont

Seite 11

200-2341 19GGGGEEEENNNNEEEERRRRAAAATTTTOOOORRRR SSSSPPPPEEEECCCCIIIIFFFFIIIICCCCAAAATTTTIIIIOOOONNNNSSSSEEEENNNNGGGGIIIINNNNEEEE SSSSPPPPEEEECCCCIII

Seite 12 - 12 200-2341

2 200-2341Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 13 - FUEL CONSUMPTION TABLE

20 200-2341EEEELLLLEEEECCCCTTTTRRRRIIIICCCCAAAALLLLSSSSPPPPEEEECCCCIIIIFFFFIIIICCCCAAAATTTTIIIIOOOONNNNSSSSFFFFUUUUEEEELLLLSSSSPPPPEEEECCCCIIIIFFFFIII

Seite 14 - WWAARRNNIINNGG

200-2341 21Before installing, operating or maintaining thegenerator, take a few moments to become familiar withthe features of the generator as illust

Seite 15 - Propane Vapor (LPG)

22 200-2341A standby generator is an engine driven air cooledsystem to convert the energy contained in either liquidpropane vapor or natural gas to el

Seite 16

200-2341 23Two methods are available to start the generator.The automatic, or AUTO mode is for use with anautomatic transfer switch. With the control

Seite 17 - CCAAUUTTIIOONN

24 200-2341Status indicator lights relay conditions of generatorfunction for user or service technician convenience.Illumination of these indicator li

Seite 18

200-2341 251. Perform first change at 25 hours.MMMMAAAAIIIINNNNTTTTEEEENNNNAAAANNNNCCCCEEEEEvery monthor 15 hoursEvery 6 monthsor 100 hoursEvery year

Seite 19

26 200-2341Prior to checking the oil level, start the generator bymoving the Mode switch on the control panel to the RUNposition. Allow the generator

Seite 20

200-2341 27Selection of the correct grade and type of engine oilgreatly affects the performance of the generator,especially when starting. Before sel

Seite 21

28 200-2341The generator engine is equipped with a dry elementair filter to block particles in the combustion air fromgetting into the engine and caus

Seite 22

200-2341 295. Insure the the battery charger is powered and functioning properly. A correctly operating battery charger displays lights on the face

Seite 23

200-2341 3Do not attempt to install the generator yourself. Extremely high and dangerous electrical voltages are present in utility power source lines

Seite 24

30 200-2341Engine spark plugs are an important part of theengine ignition system. Worn or incorrectly adjustedspark plugs can negatively affect engin

Seite 25

200-2341 31In some areas of the United States, a USDA ForestService approved exhaust spark arrestor is legallyrequired. This optional accessory is ad

Seite 26

32 200-2341Proper cooling of the generator is vital to maintainperformance and prevent equipment failure. Blockedcabinet openings or other airflow ob

Seite 27

200-2341 33Over time, normal engine operation leads to wear inthe engine valve train which decreases generator output.To restore generator output, it

Seite 28

34 200-2341TTTTRRRROOOOUUUUBBBBLLLLEEEESSSSHHHHOOOOOOOOTTTTIIIINNNNGGGGSYMPTOM POSSIBLE CAUSE CORRECTIVE ACTIONEngine does not crank Loose battery cab

Seite 29 - Display Operating Condition

200-2341 35TTTTRRRROOOOUUUUBBBBLLLLEEEESSSSHHHHOOOOOOOOTTTTIIIINNNNGGGGSYMPTOM POSSIBLE CAUSE CORRECTIVE ACTIONLow generator output voltage Low engine

Seite 30

36 200-2341PPAARRTTSS DDRRAAWWIINNGG -- EEXXHHAAUUSSTT SSYYSSTTEEMM PPAARRTTSS LLIISSTT Item Part No Qty Description1 N/A 9 Screw, 10-16

Seite 31

200-2341 37PPAARRTTSS LLIISSTT PPAARRTTSS DDRRAAWWIINNGG -- EENNCCLLOOSSUURREEItem Part No Qty Description1 N/A 14 Screw, 10-16 x .50” lg2

Seite 32

38 200-2341PPAARRTTSS DDRRAAWWIINNGG -- LLIIDD AASSSSEEMMBBLLYYPPAARRTTSS LLIISSTT Item Part No Qty Description1 0056765 1 Lock (includes 1A

Seite 33

200-2341 39PPAARRTTSS DDRRAAWWIINNGG -- GGEENNEERRAATTOORR PPAARRTTSS LLIISSTT Item Part No Qty Description1 0056629 1 Discharge louvered

Seite 34 - 34 200-2341

4 200-2341The National Electrical Code (NEC) requires the frame and external electrically conductive parts of the generator to be connected to an appr

Seite 35 - 200-2341 35

40 200-2341PPAARRTTSS DDRRAAWWIINNGG --HH22XX BBRREEAAKKDDOOWWNNPPAARRTTSS LLIISSTT Item Part No Qty Description1 094-0091 1 Insulation2 115-

Seite 36 - 36 200-2341

200-2341 41PPAARRTTSS DDRRAAWWIINNGG -- EENNGGIINNEE PPAANNEELLEENNDD AASSSSEEMMBBLLYYPPAARRTTSS LLIISSTT Item Part No Qty Description1 094-

Seite 37 - 200-2341 37

42 200-2341PPAARRTTSS DDRRAAWWIINNGG -- CCOONNTTRROOLLPPAANNEELLBBRREEAAKKDDOOWWNNPPAARRTTSS LLIISSTT Item Part No Qty Description1 N/A 2 Sc

Seite 38 - 38 200-2341

200-2341 43PPAARRTTSS DDRRAAWWIINNGG -- BBAATTTTEERRYYHHOOLLDD DDOOWWNNPPAARRTTSS LLIISSTT Item Part No Qty Description1 N/A 2 Nut, 1/4-202

Seite 39 - 200-2341 39

44 200-2341NNOOTTEESS

Seite 40 - 40 200-2341

200-2341 45NNOOTTEESS

Seite 41 - 200-2341 41

46 200-2341Coleman PowerStation™ Stationary Standby3-Year or 1500 Hour Limited WarrantyYour Coleman PowerStation™ emergency back up power system gener

Seite 42 - 42 200-2341

200-2341 47COMUNÍQUESE CON EL DEPARTAMENTO DE SERVICIO DE PRODUCTOS COLEMANPOWERMATE EN EL TELÉFONO1-800-445-1805para obtener información sobre servic

Seite 44 - 44 200-2341

200-2341 5The stationary standby electric generator ismanufactured for our customers to supply reliablebackup power. The generator is a compact unit,

Seite 45 - 200-2341 45

6 200-2341Proper location of the generator set is important toinsure safe and reliable operation and can aid in theinstallation of the generator. When

Seite 46 - Implied Warranties:

200-2341 7When connecting the generator to a buildingelectrical distribution system, use of a transfer switch isrecommended to isolate the normal util

Seite 47 - 200-2341 47

8 200-2341Once installation planning is complete and allnecessary local permits are granted, installation of thegenerator may begin. Within the follo

Seite 48 - 200-2341

200-2341 9IIIINNNNSSSSTTTTAAAALLLLLLLLAAAATTTTIIIIOOOONNNN DDDDRRRRAAAAWWWWIIIINNNNGGGGSSSS